A HOME OF LABORATORY EQUIPMENT SALES & SERVICE PROVIDER

Brand: Labstac

Model:ANA57-150SP

Origin: USA

Features:

Auto Chemistry Analyzer used to measure different chemicals and clinical chemistry of human biological samples.

Used in Research, Hospital, Clinical chemistry, Laboratory, Pharmaceutical

Also known as Routine biochemistry analyzers

  • 150 Sample positions
  • 160 Reaction cuvettes
  • 180 Refrigerated reagent positions
  • Optical filter/fiber bragg grating selectable
  • 800 Tests per hour (1200 Tests with ISE module)
  • Built-in sample barcode system optional
  • Probe with anti-collision function,liquid level detection function.

Specification:

Overall Performance:
      Throughput 800 Tests/hour, 1200Tests/hour with ISE(Optional)
      Analysis Method End-point, Fixed-time, Rate(Kinetic)
      Certificates CE, FDA, ISO9001, IS013485
Sample & Reagent System:
      Sample Positions 150 sample positions
      Reagent Positions 180 reagent positions
      Sample Volume 1~70 μl
      Reagent Volume 10~350 μl
      Probe Teflon coating, with anti-collision function, liquid level detection function
      Probe Washing Automatic washing interior and exterior
      Reagent Cooling Refrigerated tray with independent switch
Reaction System:
      Temperature Control Water bath, 37±0.1°C, real-time monitoring
      Cuvettes 160 reusable cuvettes, optical length 6mm
      Mixer Probe Independent stirring
      Washing Automatic cuvettes washing
      STAT Function YES
Optical System:
      Light Source 12 V/20 W halogen lamp/fiber bragg grating optional
      Spectrophotometry Post-spectral spectrophotometry
      Wavelength 12 wavelengths from 340~800nm
      Absorbance 0~3.5 Abs
Calibration & QC:
      Calibration Linear: K factor, 1-point, 2-point and multipoint linear Non-Linear: Spline, Polygon, Index, Ogarithm, Logit-4P, Logit-5P
      Quality Control Real-time QC, Westgard multi rule, Cumulative Sum Check, Twin Plot(2D)
Data Management:
      Software Windows 7/8/10, 32 or 64 bit
      LIS System Bi-direction, support HL7 protocol
      Interface LAN port access
      Printer External, multiple reporting mode available
Working Conditions:
      Power Supply AC220 V±10% 50/60 HZ, 110 V±10% 60 Hz, 1500 W
      Temperature 15~30°C (±2°C)
      Water Consumption Deionized water: <25L/H
      Humidity 40%~85%
Size & Weight:
      External Size (W*D*H) 1360x795x1155 mm
      Net Weight 290 kg
      Package Size (W*D*H) 1718x958x1427 mm
      Gross Weight 400 kg